A Truss Cross connects two trusses that cross or overlap. This lets Production Assist transfer forces between the two structural members and account for the connection in the static calculation.
This page explains how to create a Truss Cross manually, choose the appropriate connection type, and check the connection.
For an overview of Truss Crosses, Drops, and other connections, see Insert Connections. For the Vectorworks workflow with bearing height, automatic detection, and Drops, see Connections in Vectorworks.
Before inserting a Truss Cross, both trusses must:
An overlap in plan view alone is not sufficient. There must be a vertical distance between the structural axes: the Truss Cross connects the two detected structures across that distance. Check the crossing in a 3D or side view as well.
If you have already selected the structural objects, you can instead run Rigging → Connections → Create Truss Cross. This command finds suitable crossings within the selection and inserts the connections without opening a dialog. See Rigging → Connections for the command's requirements and result.

After insertion, the calculation must recognize both trusses as one connected system. Use Select System Objects to check which objects Production Assist assigns to this structural system.
Production Assist can detect suitable crossings automatically during calculation. The File → Settings... → App → Generate Truss Cross automatically option is enabled by default. Detection considers the position and direction of the structural members, their vertical separation, their cross sections, and whether the members allow Truss Crosses. A visible crossing therefore does not always result in a connection.
Enable Allow Truss Cross in the same Object to include crossings between structural members in the same object. For a partial calculation, Auto Add Truss Crosses when using partial calculation also includes existing Truss Crosses in the calculation scope. Both options are disabled by default.
Stack Truss only aligns the height of a detected second truss system; it does not create a Truss Cross.
Automatic detection does not replace checking the geometry and structural behavior. Check every generated Truss Cross in the model and in the calculation results.
Select the Truss Cross object and set the appropriate load-bearing behavior under Object Properties → Truss Cross Type. New Truss Crosses initially use Rigid. The available values are:
| Truss Cross Type | Behavior in the model | Typical use |
|---|---|---|
| Flexible | Allows rotation in all directions. | A hinged bearing that transfers no moments. |
| Compression Only | Transfers compressive forces only. | A truss resting on a bearing that can lift off it. |
| Tension Only | Transfers tensile forces only. | A tension-loaded connection that must not transfer compressive forces. |
| Rigid | Transfers forces and moments without relative movement. | A structurally rigid, moment-resisting connection. |
| None | Excludes the Truss Cross from the static calculation. | When the connection should have no effect in the calculation model. |
Choose a type that matches the actual structural connection. A geometrically detected crossing is not automatically hinged, compression-resistant, tension-resistant, or rigid.
The Truss Cross Truss Cross Force and Truss Cross Force Characteristic values appear under Object Properties. These are result values: the design value includes safety factors, while the characteristic value does not. Both fields are read-only.
After the calculation, check:
Check the following in order:
For other object properties, see Object Properties. The related global options are described in Settings.
Note: A Truss Cross represents the assumed structural behavior in the calculation model. It does not replace selecting a real connector or checking its structural design and capacity.