Documentation

Glossary

Model an LED Wall with Structural Lines#

This guide explains how to model an LED wall for structural calculation. The visible LED panels and the calculable supporting structure serve different purposes: the panels represent the wall and its weight, while Structural Lines describe the load-bearing profiles. This method works for LED walls supported by trusses, ladder trusses, or a custom frame.

In Vectorworks, Production Assist can also read a parametric LED Wall object. If it contains panels, the integration automatically creates a simplified structural model from them. Production Assist reads the total weight from the LED Wall object. If the object has no panels, the integration uses its object path and height to create a simplified structural model. In AutoCAD or a manually built model, assign the load-bearing Structural Lines yourself under File > Settings... > Structural Lines. AutoCAD does not have an equivalent automatic LED Wall generator.

Important: This guide describes how to model the structural system. It does not replace structural design, manufacturer specifications, or inspection of the actual connection hardware.

Basic principles#

Three things must be consistent for an LED wall to be calculable:

  1. Geometry: The visible panels and frame are in the correct positions.
  2. Structure: The load-bearing components are represented by connected centerlines and have valid cross sections.
  3. Loads and supports: Panel weight, frame weight, and the actual supports or suspension points are defined.

A 3D surface or a group of panels alone is not enough for structural calculation. Production Assist needs a connected structure that transfers the forces from the LED panels through the profiles to the supports.

Requirements#

  • A current version of Production Assist with CAD integration enabled.
  • For automatic LED Wall import: Vectorworks with the Production Assist integration enabled and a parametric LED Wall object.
  • For a manual CAD model: a drawing in Vectorworks or AutoCAD. In Vectorworks, assign classes from the symbol definition; in AutoCAD, assign layers from a block definition.
  • The dimensions of the LED panels, frame or ladder truss, and the profiles actually used.
  • The self-weight of an LED panel, including its rear panel, power supplies, and accessories.
  • Valid Ground Support Attachments or suspension points.

Step by step: Build an LED wall from lines#

1. Define the structure and load path#

First decide how the LED wall is actually supported. Do not draw only the visible outer contour; plan the load path:

  • Where does the panel rest on the lower truss or profile?
  • Where is the vertical connection or ladder truss?
  • Which profiles connect the individual rows of panels?
  • Where are the Ground Support Attachments, or where do the suspension points connect?

For a simple freestanding setup, for example, a horizontal support line, a vertical connecting line, and the upper or side frame line form the basic structural system. The horizontal line represents the support or resting position of the LED panel; the vertical line extends or connects it to the frame. This description applies to a manually modeled structure. The automatically generated Vectorworks model follows the panel geometry and does not replace a check that it represents the actual load path.

2. Configure Structural Lines#

  1. Open File > Settings... > Structural Lines.
  2. Under Layers for Structures, create an assignment for the class or layer used for the LED wall structure.
  3. In the Cross Section field, assign the cross section used by each profile.
  4. If needed, create separate assignments for main profiles, vertical profiles, and connecting parts.
  5. To create supports from points in the CAD drawing, assign the class or layer under Layers for Supports and choose the Ground type for points. Lines on a support layer are interpreted as ropes.

Class and layer names are up to you. What matters is how they are assigned in Structural Lines.

3. Draw the centerlines#

For a manual workflow, draw the load-bearing components as lines in the symbol or block definition: in Vectorworks, in a 2D or 3D component of the symbol; in AutoCAD, inside the block definition. Standalone CAD lines outside a symbol or block are not imported through these assignments.

  1. Activate the class or layer configured under Layers for Structures.
  2. Draw the centerline of the lower support.
  3. Draw the vertical or diagonal connections.
  4. Draw the upper and side frame profiles.
  5. Repeat the lines for each profile that has a different cross section or material.

The lines must actually connect at the nodes. A visual crossing is not enough: the endpoint of a line must lie on the endpoint or line of the adjoining component. For separate line segments, their start and end points must coincide exactly. Open or merely overlapping lines create disconnected structural components.

4. Prepare the LED panels as symbols#

The visible panels should be symbols so that you can duplicate, edit, and manage them as related elements.

  1. Draw the geometry for one panel or the desired panel group.
  2. Create a symbol from it.
  3. Place the symbol on the intended line or at the intended connection.
  4. Duplicate the panel at regular intervals.

Use Paste Offset to repeat panels at regular intervals. When Auto Paste Offset is enabled, Production Assist uses the selected object's structural dimension. Use Duplicate X/Y/Z or the corresponding duplicate commands to build rows and columns quickly.

5. Choose cross sections for the LED wall#

In the Resource Manager, open Cross Section Templates and choose a suitable cross section for each load-bearing profile. Use the properties of the profile actually installed or a verified manufacturer's cross section. The supplied LED Wall cross section is a simplified default used by the Vectorworks integration for automatically generated LED Wall structural elements. Its properties do not automatically represent a specific panel or frame profile. Do not use it instead of the actual profile data for a manually modeled structure. The LED Aluvision LED Wall cross section is also available for Aluvision components. There is no general LED Covers cross section in the default templates.

For the connection between an LED panel and a ladder truss, use the cross section of the profile actually installed. Do not assign a default cross section just because the part looks similar.

6. Check panel weight and material#

A cross section describes the properties of a load-bearing profile. It does not automatically describe the total weight of an LED panel, including its electronics, frame, power supplies, and accessories.

  • For profiles, Production Assist can calculate the weight from the cross section and material, unless a custom object weight has been specified.
  • For a parametric Vectorworks LED Wall object, the integration reads the total weight of the panels and accessories from the object. In a manually built model, enter or assign the actual panel weight in Object Properties or in the symbol being used.
  • Check whether the panel is used as a load and whether accessories such as mounts, power supplies, or cables should be included.

7. Add supports and connections#

Create the actual supports according to the modeling method you chose:

  • Use CAD points on a class or layer assigned the Ground type under Layers for Supports.
  • Or use New Object > Ground Support Attachment in Point insertion mode, or add suitable suspension points. For instructions on inserting and configuring a Ground Support Attachment, see Insert and configure Ground Support Attachments.

Supports must be located at the actual structural nodes. If the structure stands on the floor, visible panel edges alone do not define the supports. If the LED wall is suspended, connect the suspension points to the upper structure. For a parametric Vectorworks object, check in particular that the automatically generated connections and support points match the actual construction.

A separately drawn clamp or connecting part is not required for a structural connection. The important thing is that the Structural Lines meet and connect at the correct points. Production Assist can derive the connection from them.

8. Read the drawing again and calculate#

  1. Read the Vectorworks drawing again using File > Vectorworks Integration > Read Vectorworks Drawing.... In AutoCAD, use File > AutoCAD Integration > Read AutoCAD Drawing....
  2. In the Renderer, check that all lines are recognized as structures.
  3. Check that the LED panels are suspended from or resting on the expected structure.
  4. In the Scene Tree, check that the elements belong to the correct Assembly Group.
  5. Run the structural calculation.
  6. Check the deformation, support forces, self-weight, and warnings.

If the calculation reports a disconnected structure, missing supports, or unconnected lines, first correct the geometry and Structural Lines assignments. A visual adjustment in the Renderer does not fix a missing structural connection.

Create custom cross sections from DWG profiles#

The DWG profile feature can also create custom profiles for LED walls, covers, brackets, or ladder trusses. Use it when the supplied templates do not include the actual cross section.

1. Prepare the DWG profile#

Draw the cross section of the actual profile in a separate DWG file:

  1. Draw the cross section at 1:1 scale using consistent units.
  2. Use closed polylines or individual lines whose endpoints coincide exactly.
  3. For hollow profiles, also draw the inner contour as a closed shape.
  4. Remove dimensions, text, construction lines, and geometry that is not part of the cross section.
  5. Check that there are no gaps, duplicate lines, or self-intersecting contours.

The DWG importer looks for closed polygons. It can join individual open lines into a polygon only when their endpoints coincide exactly. An open contour cannot be calculated as a cross section.

For hollow profiles, the area of the inner contour is subtracted from the enclosing outer contour. The order and drawing direction of the contours do not matter. This also applies to thin-walled profiles with closely spaced inner and outer contours.

2. Convert the DWG to a JSON cross section#

Convert the profile in the desktop app:

  1. In the desktop app, open File > Export Selected DWG Cross Section....
  2. Select the prepared .dwg or .dxf file.
  3. Production Assist calculates the area, centroid, area moments of inertia, section moduli, and other properties from the contour.
  4. A .json file containing the cross-section data and a .png preview are saved in the same folder.

The generated JSON file contains the structural data required for calculation. Use the PNG preview to check the detected contour before importing it.

3. Import the JSON cross section#

  1. Open the Resource Manager in Production Assist.
  2. Go to Cross Section Templates.
  3. Import the generated JSON file using File > Import JSON > IMPORT CROSS SECTION.
  4. Give it a unique name, for example Manufacturer - LED frame 80x40.
  5. Check the displayed dimensions and properties.
  6. Under File > Settings... > Structural Lines, assign the new cross section to the appropriate layer or class in the Cross Section field.

Then use this cross section for all Structural Lines representing that component. Create separate cross sections for profile segments with different dimensions.

4. Profiles with changing geometry#

If a component is larger at one end and smaller at the other, use the smaller or weaker cross section for the structural check, unless you model the component as separate segments with different cross sections. This avoids overstating its load-bearing capacity by assigning a cross section that is too large.

5. Check the DWG import#

After importing, check:

  • the cross-section width and height,
  • the area and material assignment,
  • the cross-section orientation in the structure,
  • inner contours in hollow profiles,
  • the PNG preview, and
  • the results of a short test calculation.

If the preview is rotated, incomplete, or blank, correct the DWG contour and export it again. Do not change the calculated properties manually to compensate for incorrect geometry.

The cross-sectional area must be positive. If the combination of contours does not produce a positive area, the export stops with an error message. If an earlier export produced negative areas or negative area moments of inertia, export the original DWG profile again with the current version and import the corrected JSON file.

Checklist before approval#

  • Are all panel rows and frame profiles represented as symbols or structural elements?
  • Are the centerlines closed and actually connected at every node?
  • Is the actual cross section assigned to every profile?
  • Is the panel weight, including relevant accessories, correct?
  • Are Ground Support Attachments or suspension points defined at the actual connection nodes?
  • Do all components belong to the intended structural system?
  • Are deformation, support forces, and possible uplift forces plausible?
  • Do the profiles used match the actual construction and manufacturer data?

Further information#